Daewoo DTH 21S8 User Manual

S/M No : TCM101S001  
Service Manual  
Color Television  
CHSSIS MODEL  
CM-101S DTH-21S7  
DTH-21S8  
Caution  
: In this Manual, some parts can be changed for improving. their  
performance without notice in the parts list. So, if you need the  
latest parts information, please refer to PPL(Parts Price List)in  
Service Information Center.  
April. 2007  
SAFETY PRECAUTIONS  
CAUTION : DO NOT ATTEMPT TO MODIFY THIS PRODUCT IN ANY WAY. SUBJECT : X-RADIATION  
NEVER PERFORM CUSTOMIZED INSTALLATIONS WITHOUT MANUFAC-  
TURER'S APPROVAL. UNAUTHORIZED MODIFICATIONS WILL NOT ONLY VOID  
THE WARRANTY, BUT MAY LEAD TO YOUR BEING LIABLE FOR ANT RESULT-  
ING PROPERTY DAMAGE OR USER INJURY.  
SERVICE WORK SHOULD BE PERFORMED ONLY AFTER YOU ARE THOR-  
OUGHLY FAMILIAR WITH ALL OF THE FOLLOWING SAFETY CHECKS AND  
SERVICING GUIDELINES. TO DO OTHERWISE, INCREASES THE RISK OF  
POTENTIAL HAZARDS AND INJURY TO THE USER.  
1. BE SURE PROCEDURES AND INSTRUCTIONS TO ALL SERVICE PERSON-  
NEL COVER THE SUBJECT OF X-RADIATION. THE ONLY POTENTIAL  
SOURCE OF X-RAYS IN CURRENT T.V. RECEIVERS IS THE PICTURE TUBE.  
HOWEVER, THIS TUBE DOES NOT EMIT X-RAYS WHEN THE HIGH VOLT-  
AGE IS AT THE FACTORY SPECIFIED LEVEL. THE PROPER VALUE IS GIVEN  
IN THE APPLICABLE SCHEMATIC. OPERATION AT HIGHER VOLT-AGES MAY  
CAUSE A FAILURE OF THE PICTURE TUBE OR HIGH VOLTAGE SUPPLY  
AND UNDER CERTAIN CIRCUMSTANCES, AMY PRODUCE RADIA-TION IN  
EXCESS OF DESIRABLE LEVELS.  
WHILE SERVICING, USE AN ISOLATION TRANSFORMER FOR PROTECTION  
FROM A.C. LINE SHOCK.  
2. ONLY FACTORY SPECIFIED C.R.T ANODE CONNECTORS MUST BE  
USED.DEGAUSSING SHIELDS ALSO SERVE AS X-RAY SHIELD IN COLOR  
SETS. ALWAYS RE-INSTALL THEM.  
SAFETY CHECKS  
AFTER THE ORIGINAL SERVICE PROBLEM HAS BEEN CORRECTED, A CHECK  
SHOULD BE MADE OF THE FOLLOWING:  
3. IT IS ESSENTIAL THAT SERVICE PERSONNEL HAVE AVAILABLE AN ACCU-  
RATE AND RELIABLE HIGH VOLTAGE METER. THE CALIBRATION OF THE  
METER SHOULD BE CHECKED PERIODICALLY AGAINST A REFERENCE  
STANDARD. SUCH AS THE ONE AVAILABLE AT YOUR DISTRIBUTOR.  
4. WHEN THE HIGH VOLTAGE CIRCUITRY IS OPERATING PROPERLY THERE  
IS NO POSSIBILITY OF AN X-RADIATION PROBLEM. EVERY TIME A COLOR  
CHASSIS IS SERVICED, THE BRIGHTNESS SHOULD BE RUN UP AND DOWN  
WHILE MONITORING THE HIGH VOLTAGE WITH A METER TO BE CERTAIN  
THAT THE HIGH VOLTAGE DOES NOT EXCEED THE SPECIFIED VALUE AND  
THAT IT IS REGULATING CORRECTLY. WE SUGGEST THAT YOU AND YOUR  
SERVICE ORGANIZATION REVIEW TEST PROCEDURES SO THAT VOLTAGE  
REGULATION IS ALWAYS CHECKED AS A STANDARD SERVICING  
PROCEDURE, AND THAT THE HIGH VOLTAGE READING BE RECORDED ON  
EACH CUSTOMER’S INVOICE.  
5. WHEN TROUBLESHOOTING AND MAKING TEST MEASUREMENTS IN A  
PRODUCT WITH A PROBLEM OF EXCESSIVE HIGH VOLTAGE, AVOID BEING  
UNNECESSARILY CLOSE TO THE PICTURE TUBE AND THE HIGH VOLTAGE  
SUPPLY. DO NOT OPERATE THE PRODUCT LONGER THAN IS NECESSARY  
TO LOCATE THE CAUSE OF EXCESSIVE VOLTAGE.  
6. REFER TO HV, B+ AND SHUTDOWN ADJUSTMENT PROCEDURES  
DESCRIBED IN THE APPROPRIATE SCHEMATIC AND DIAGRAMS (WHERE  
USED).  
SUBJECT:FIRE & SHOCK HAZARD  
1. BE SURE THAT ALL COMPONENTS ARE POSITIONED IN SUCH A WAY AS  
TO AVOID POSSIBILITY OF ADJACENT COMPONENT SHORTS. THIS IS  
ESPECIALLY IMPORTANT ON THOSE MODULES WHICH ARE TRANS-  
PORTED TO AND FROM THE REPAIR SHOP.  
2. NEVER RELEASE A REPAIR UNLESS ALL PROTECTIVE DEVICES SUCH AS  
INSULATORS, BARRIERS, COVERS, SHIELDS, STRAIN RELIEFS, POWER  
SUPPLY CORDS, AND OTHER HARDWARE HAVE BEEN REINSTALLED PER  
ORIGINAL DESIGN. BE SURE, THAT THE SAFETY PURPOSE OF THE  
POLARIZED LINE PLUG HAS NOT BEEN DEFEATED.  
3. SOLDERING MUST BE INSPECTED TO DISCOVER POSSIBLE COLD SOL-  
DER JOINTS, SOLDER SPLASHES OF SHARP SOLDER POINTS. BE CER-  
TAIN TO REMOVE ALL LOOSE FOREIGN PARTICLES.  
4. CHECK FOR PHYSICAL EVIDENCE OF DAMAGE OR DETERIORATION TO  
PARTS AND COMPONENTS, FOR FRAYED LEADS, DAMAGED INSULATION  
(INCLUDING A.C. CORD), AND REPLACE IF NECESSARY. FOLLOW ORIGI-  
NAL LAYOUT, LEAD LENGTH AND DRESS.  
5. NO LEAD OR COMPONENT SHOULD TOUCH A RECEIVING TUBE OR A  
RESISTOR RATED AT 1 WATT OR MORE. LEAD TENSION AROUND PRO-  
TRUDING METAL SURFACES MUST BE AVOIDED.  
6. ALL CRITICAL COMPONENTS SUCH AS FUSES, FLAMEPROOF RESISTOR,  
CAPACITORS, ETC. MUST BE REPLACED WITH EXACT FACTORY TYPES.  
DO NOT USE REPLACEMENT COMPONENTS OTHER THAN THOSE SPECI-  
FIED OR MAKE UNRECOMMENDED CIRCUIT MODIFICATIONS.  
SUBJECT : IMPLOSION  
1. ALL DIRECT VIEWED PICTURE TUBES ARE EQUIPPED WITH AN INTEGRA  
IMPLOSION PROTECTION SYSTEM. BUT CARE SHOULD BE TAKEN TO  
AVOID DAMAGE DURING INSTALLATION. AVOID SCRATCHING THE TUBE.  
OF SCRATCHED REPLACE IT.  
7. AFTER RE-ASSEMBLY OF THE STE ALWAYS PERFORM AN A.C. LEAKAGE  
TEST ON ALL EXPOSED METALLIC PARTS OF THE CABINET. (THE CHAN-  
NEL SELECTOR KNOB, ANTENNA TERMINALS, HANDLE AND SCREWS) TO  
BE SURE THE SET IS SAFE TO OPERATE WITHOUT DANGER OF ELECTRI-  
CAL SHOCK. DO NOT USE A LINE ISOLATION TRANSFORMER DURING THIS  
TEST USE AN A.C. VOLTMETER, HAVING 5000 OHMS PER VOLT OR MORE  
SENSITIVITY, IN THE FOLLOWING MANNER : CONNECT A 1500 OHM 10  
WATT RESISTOR, PARALLELED BY A .15 MFD. 150V A.C. TYPE CAPACI-  
TOR BETWEEN A KNOWN GOOD EARTH GROUND (WATER POPE, CON-  
DUIT, ETC.) AND THE EXPOSED METALLIC PARTS, ONE AT A TIME.  
MEASURE THE A.C. VOLTAGE ACROSS THE COMBINATION OF 1500 OHM  
RESISTOR AND .15 MFD CAPACITOR. REVERSE THE A.C. PLUG AND  
REPEAT A.C. VOLTAGE MEASUREMENTS FOR EACH EXPOSED METALLIC  
PART. VOLTAGE MEASURED MUST NOT EXCEED .75 VOLTS R.M.S THIS  
CORRESPONDS TO 0.5 MILLIAMP A.C. NAY VALUE EXCEEDING THIS LIMIT  
CONSTITUTES A POTENTIAL SHOCK HAZARD AND MUST BE CORRECTED  
IMMEDIATELY.  
2. USE ONLY RECOMMENDED FACTORY REPLACEMENT TUBES.  
SUBJECT : TIPS ON PROPER INSTALLATION  
1. NEVER INSTALL ANY PRODUCT IN A CLOSED-IN RECESS, CUBBYHOLE OR  
CLOSELY FITTING SHELF SPACE, OVER OR CLOSE TO HEAT DUCT, OR IN  
THE PATH OF HEATED AIR FLOW.  
2. AVOID CONDITIONS OF HIGH HUMIDITY SUCH AS: OUTDOOR PATIO  
INSTALLATIONS WHERE DEW IS A FACTOR, NEAR STEAM RADIATORS  
WHERE STEAM LEAKAGE IS A FACTOR, ETC.  
3. AVOID PLACEMENT WHERE DRAPERIES MAY OBSTRUCT REAR VENTING.  
THE CUSTOMER SHOULD ALSO AVOID THE USE OF DECORATIVE  
SCARVES OR OTHER COVERINGS WHICH MIGHT OBSTRUCT VENTILA-  
TION.  
4. WALL AND SHELF MOUNTED INSTALLATIONS USING A COMMERCIAL  
MOUNTING KIT, MUST FOLLOW THE FACTORY APPROVED MOUNTING  
INSTRUCTIONS. A PRODUCT MOUNTED TO A SHELF OR PLATFORM MUST  
RETAIN ITS ORIGINAL FEET (OR THE EQUIVALENT THICKNESS IN SPAC-  
ERS)TO PROVIDE ADEQUATE AIR FLOW ACROSS THE BOTTOM, BOLTS OR  
SCREWS USED FOR FASTENERS MUST NOT TOUCH ANY PARTS OR  
WIRING. PERFORM LEAKAGE TEST ON CUSTOMIZED INSTALLATIONS.  
5. CAUTION CUSTOMERS AGAINST THE MOUNTING OF A PRODUCT ON  
SLOPING SHELF OR A TILTED POSITION, UNLESS THE PRODUCT IS  
PROPERLY SECURED.  
6. A PRODUCT ON A ROLL-ABOUT CART SHOULD BE STABLE ON ITS MOUNT-  
ING TO THE CART. CAUTION THE CUSTOMER ON THE HAZARDS OF TRY-  
ING TO ROLL A CART WITH SMALL CASTERS ACROSS THRESHOLDS OR  
DEEP PILE CARPETS.  
7. CAUTION CUSTOMERS AGAINST THE USE OF A CART OR STAND WHICH  
HAS NOT BEEN LISTED BY UNDERWRITERS LABORATORIES. INC. FOR  
USE WITH THEIR SPECIFIC MODEL OF TELEVISION RECEIVER OR  
GENERICALLY APPROVED FOR USE WITH T.V.S OF THE SAME OR LARGER  
SCREEN SIZE.  
A.C. VOLTMETER  
GOOD EARTH GROUND  
SUCH AS THE WATER  
PIPE, CONDUIT, ETC.  
PLACE THIS PROBE  
ON EACH EXPOSED  
METAL PART  
1500  
OHM  
10WATT  
SUBJECT : GRAPHIC SYMBOLS  
THE LIGHTNING FLASH WITH ARROWHEAD SYMBOL,  
WITHIN AN EQUILATERAL TRIANGLE, IS INTENDED TO  
ALERT THE SERVICE PERSONNEL TO THE PRES-ENCE  
OF UNINSULATED “DANGEROUS VOLTAGE”  
THAT MAY BE OF SUFFICIENT MAGNITUDE TO CON-  
STITUTE A RISK OF ELECTRIC SHOCK.  
8. CAUTION CUSTOMERS AGAINST THE USE OF EXTENSION CORDS,  
EXPLAIN THAT A FOREST OF EXTENSIONS SPROUTING FROM A SINGLE  
OUTLET CAN LEAD TO DISASTROUS CONSEQUENCES TO HOME AND  
FAMILY.  
THE EXCLAMATION POINT WITHIN AN EQUILATERAL  
TRIANGLE IS INTENDED TO ALERT THE SERVICE  
PERSONNEL TO THE PRESENCE OF IMPORTANT  
SAFETY INFORMATION ON SERVICE LITERATURE.  
-2-  
SPECIFICTION  
Model  
DTH-21S7 / 21S8  
Item  
CHASSIS  
CM-101S  
TV Standard  
Power Input  
NTSC-M, PAL-N, PAL-M  
AC 220V, 50/60Hz  
Power Consumption  
Tuning System  
Tuning Ranges  
80W  
Frequency Synthesizer(FS) Tuning System  
TV  
VHF(L) : CH2 - CH6  
UHF(H) : CH7 - CH13  
UHF : CH14 - CH69  
CATV VHF(L) : 5A, A,B,A-5-A-1,CH2-CH6  
VHF(H) : C-W+11,CH7 - CH13  
UHF : W+12-W+84  
Sound Output  
5W + 5W  
Speaker  
8 ohm 5W x 2EA  
Antenna Input Impedance  
Auxiliary Input Terminal  
75 ohm Unbalanced  
Side : Video, Audio(L,R) - AV2, Headphone  
Rear : Video, Audio(L,R) - AV1  
Y, Cb, Cr, Audio(L,R) - CVI  
Picture IF Carrier Frequency : 45.75MHz  
Sound IF Carrier Frequency : 41.25MHz  
Color Sub-Carrier Frequency :  
NTSC-M : 3.579545 Mhz  
PAL-N : 3.582056 Mhz  
Intermediate Frequencies  
PAL-M : 3.575611 Mhz  
Remote Control  
Special Function  
R-48C04(AAA)  
1) Closed Caption  
2) Channel Label  
-3-